ElectroPermanent Chuck Control Unit

The ElectroPermanent Chuck Control Unit is used as the power supply for MPI ElectroPerm

...read more

ElectroPermanent Chuck Control Unit

  • Operational safety – the machine cannot be started up at a low holding force
  • Setting of the safe magnetization level
  • Effective demagnetization of the chuck and the workpiece for easy removal
  • Possible control of the chuck via remote controller
  • Possibility to control one or more magnets at the same time (depending on selected unit type)
  • One (1) year warranty

The ElectroPermanent Chuck Control Units are designed to magnetize and demagnetize all types of ElectroPermanent magnetic devices depending on its factory settings. The magnetization cycles consist of one or several positive voltage pulses. The demagnetization cycles consist of a specific combination of alternating positive and negative voltage pulses. Note: The work piece material may retain some residual magnetism due to its chemical and magnetic properties.

When to choose the ElectroPermanent Chuck Control Unit: 

The ElectroPermanent power supply and control units are designed to magnetize and demagnetize all types of ElectroPermanent magnetic devices, depending on its factory settings. MPI offers several control units depending upon size and number of chucks. In case of other magnetic device brands and models, consult MPI.
EPCU control units are named by the number of output channels (i.e., number of electrical circuits to be energized in the magnetic clamping system):

  • EPCU10: 1 channel
  • EPCU20: 2 channels
  • EPCU40: 4 channels

EPCU control units also come in two different versions:

  • SW for single wave rectified output voltage.
  • DW for double-wave (full wave) rectified output voltage.
Part Number Description Number of Chuck & Size Main Operating Voltage (Vac) Main Operating Frequency (Hz) Operating Temperature (ºF) Maximum Relative Humidity Maximum Working Altitude (ft) Cabinet Protection Class Required Circuit Breaker Required Power Cable (*) Number of Output Channels
EPCU-10SW ElectroPermanent Chuck Control Remote Control (RC-EPC) included 1 chuck sizes to 16” x 32” 200-460 50/60 32-122 90% 3,280 IP66 32A-D 3 G 4 1
EPCU-10DW ElectroPermanent Chuck Control Remote Control (RC-EPC) included 1 chuck sizes to 16” x 32” 200-460 50/60 32-122 90% 3,280 IP66 40A-D 3 G 6 2
EPCU-20SW ElectroPermanent Chuck Control for 2 chuck sizes to 16” x 32” Remote Control (RC-EPC) included 2 chuck sizes to 16” x 32” 200-460 50/60 32-122 90% 3,280 IP66 40A-D 3 G 6 4
EPCU-20DW ElectroPermanent Chuck Control Remote Control (RC-EPC) included 2 chuck sizes to 16” x 32” 200-460 50/60 32-122 90% 3,280 IP66 40A-D 3 G 6 1
EPCU-40SW ElectroPermanent Chuck Control Remote Control (RC-EPC) included 4 chuck sizes to 16” x 32” 200-460 50/60 32-122 90% 3,280 IP66 40A-D 3 G 6 2
EPCU-40DW ElectroPermanent Chuck Control Remote Control (RC-EPC) included 4 chuck sizes to 16” x 32” 200-460 50/60 32-122 90% 3,280 IP66 50A-D 3 G 10 4

*Cable between electrical grid and control unit is not supplied. Make sure to follow required cable specifications.

ElectroPermanent-Chuck-Control-Unit-dimensions-with-legend

US Customary Units

Part Number Dimensions (Inches)
  A B C D E F G H I J K
EPCU-10SW 12 10 6 9.8 7.9 0.4 9.8 7.9 8.9 6.9 0.4
EPCU-10DW 16 12 6 13.8 9.8 0.4 13.8 9.8 12.8 8.9 0.4
EPCU-20SW 16 16 8 13.8 13.8 0.4 13.8 13.8 12.8 12.8 0.4
EPCU-20DW 16 12 6 13.8 13.8 0.4 13.8 9.8 12.8 8.9 0.4
EPCU-40SW 16 16 8 13.8 13.8 0.4 13.8 13.8 12.8 12.8 0.4
EPCU-40DW 19.7 16 8 17.7 17.7 0.4 17.7 13.8 12.8 16.7 0.4

Metric Units

Part Number Dimensions (Millimeters)
  A B C D E F G H I J K
EPCU-10SW 305 254 152 249 201 254 249 201 226 175 325
EPCU-10DW 406 305 152 351 249 325 351 249 325 226 325
EPCU-20SW 406 406 203 351 351 325 351 351 325 325 325
EPCU-20DW 406 305 152 351 351 325 351 249 325 226 325
EPCU-40SW 406 406 203 351 351 325 351 351 325 325 325
EPCU-40DW 500 406 203 450 450 325 450 351 325 242 325

 

 

MPI offers two variations of the Electromagnet Control Units depending upon output voltage.

  • Electromagnet Control Unit 150W
  • Electromagnet Control Unit 630W